FRONT LOADING FLASH STERILIZERS
Price 200000 INR/ Unit
FRONT LOADING FLASH STERILIZERS Specification
- Temperature Range
- 121C to 134C
- Frequency
- 50/60 Hz
- Material
- Stainless Steel (Grade 304/316)
- Dimension (L*W*H)
- 620 x 420 x 500 mm (typical)
- Function
- Quick Steam Sterilization
- Application
- Surgical Instrument Sterilization, Medical, Laboratory
- Suitable For
- Hospitals, Clinics, Research Centers, Laboratories
- Weight
- Approx. 45 kg
- Color Code
- Silver/White
- Display Type
- Digital
- Accuracy
- 1C
- Storage Capacity
- 7-28 Liters (varies by model)
- Properties
- High Temperature Resistance, Corrosion Resistant, Quick Cycle Time
- Use
- Rapid sterilization of unwrapped medical and surgical instruments
- Power
- 2.5 kW
- Automation Grade
- Semi-Automatic/Automatic
- Product Type
- Front Loading Flash Sterilizer
- Humidity Range
- Up to 100% RH during operation
- Height
- 500 mm (approx)
- Phase
- Single Phase
- Shape
- Rectangular
- Treatment Type
- Flash Steam Sterilization
- Voltage
- 220-240V AC
- Power Source
- Electric
- Display
- Digital LED/Touch Panel
- Cycle Time
- 4-10 Minutes (Rapid Cycle)
- Drainage System
- Built-in Automatic Drain
- Chamber Pressure
- Up to 2.1 bar
- Chamber Type
- Front Loading Cylindrical/Square
- Timer
- Programmable, Up to 30 minutes
- Control System
- Microprocessor Based Controller
- Alarm Indicator
- Audio/Visual Alerts for Cycle Completion and Faults
- Noise Level
- <60 dB(A)
- Operating System
- User Friendly Interface
- Safety Features
- Automatic Pressure and Temperature Cut-off, Door Interlock System
- Water Filling
- Manual or Automatic
- Sterilization Method
- Saturated Steam Under Pressure
- Mount Type
- Table Top/Bench Top
- Door Type
- Single Hinged with Gasket Sealing
FRONT LOADING FLASH STERILIZERS Trade Information
- Minimum Order Quantity
- 1 Unit
- Payment Terms
- Cash in Advance (CID)
- Delivery Time
- 5 Days
- Sample Available
- Yes
- Sample Policy
- Within a certain price range free samples are available
- Main Domestic Market
- All India
About FRONT LOADING FLASH STERILIZERS
- B Type fully automatic front loading autoclave, capacity 22 Ltr.
- Chamber Size 250mm x 450mm, Tray 3 Nos.
- Wrapped/unwrapped, porous, solid instrument including cotton swabs can be sterilized.
- With vaccum, dry cycle & micro processor controlled.
- Inbuilt Sensor for Distilled Water.
- Digital display of pressure & temperature
- Double safety lock on the door Silicon Gasket prevents any leakage of air
- 2 Storage tanks for fresh & used water
- Diagnostic automatic alarm for any malfunctioning
Rapid and Reliable Sterilization
These flash sterilizers excel at delivering thorough steam sterilization in minimal time, ensuring instrument safety and readiness for immediate use. The advanced microprocessor-based controls maintain accurate temperatures (121C to 134C), while a built-in drainage system and programmable timer streamline overall operation for busy medical and laboratory environments.
User-Friendly Operation and Safety
Equipped with intuitive touch-panel or digital LED displays and a clear audio/visual alarm system, operating the sterilizer is straightforward even for new users. Automatic cut-off systems for pressure and temperature, along with a door interlock, enhance operator safety during each sterilization cycle.
FAQ's of FRONT LOADING FLASH STERILIZERS:
Q: How does the front loading flash sterilizer operate for rapid sterilization?
A: This sterilizer uses saturated steam under pressure to achieve quick sterilization, with cycles ranging from 4 to 10 minutes. The microprocessor controller allows users to set the desired temperature (121C to 134C) and time. Its built-in heating and drainage systems support continuous operation and fast cycling, making it ideal for rapid turnaround on unwrapped surgical and medical instruments.Q: What safety measures are included in this sterilizer?
A: Multiple safety features are built-in, including automatic pressure and temperature cut-off and a secure door interlock system to prevent the chamber from opening under unsafe conditions. Audio-visual alarms indicate cycle completion or any fault, ensuring reliability and operator safety.Q: When should I use the flash sterilizer instead of standard autoclaves?
A: Flash sterilization is ideal when you need surgical or medical instruments decontaminated quickly, such as in operating rooms or emergency cases. It saves significant time compared to conventional cycles, providing rapid turnover for unwrapped instruments in hospitals, clinics, and veterinary or research settings.Q: Where can this sterilizer be installed and used?
A: Thanks to its compact, benchtop/tabletop design and relatively light weight (approx. 45 kg), this sterilizer is suitable for installation in sterilization rooms, labs, operating rooms, clinics, or research centers. It operates on standard 220-240V AC single-phase power, making it suitable for most healthcare and laboratory environments.Q: What is the typical process for using this flash sterilizer?
A: Place unwrapped instruments inside the gasket-sealed chamber, select the desired time and temperature using the digital control, and start the cycle. The unit fills with water (manually or automatically), generates steam, maintains the set parameters, and safely drains after completion. Audio/visual alerts notify users when sterilization is done or if a fault occurs.Q: What benefits do stainless steel (Grade 304/316) chambers provide?
A: The use of high-grade stainless steel ensures resistance against both high temperatures and corrosion, which enhances hygiene, durability, and overall longevity of the unit. This is especially important in medical and laboratory environments where rigorous use is common.Q: Is the operation interface suitable for new users?
A: Yes, the sterilizer features a user-friendly digital display and interface for easy cycle setup and monitoring. Clear indicators, alarms, and straightforward controls make it accessible for both experienced professionals and staff new to sterilization processes.




























































Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Medical Autoclaves Category
HORIZONTAL CYLINDRICAL AUTOCLAVE
Price 99999 INR / Unit
Minimum Order Quantity : 1 Unit
Use : MEDICAL USE
Shape : Cylindrical
Temperature Range : 121 to 134 Degree C
Material : SS
INSTRUMENT STERILIZERS - S.S
Price 2200 INR / Unit
Minimum Order Quantity : 1 Unit
Use : Sterilizing medical and surgical instruments
Shape : Rectangular
Temperature Range : Up to 180C
Material : Stainless Steel (S.S)
Laboratory Rectangular Heating Plate with Cast Iron Top
Price 3499 INR / Unit
Minimum Order Quantity : 1 Unit
Use : Laboratory heating, sample preparation
Shape : Rectangular
Temperature Range : Ambient to 300C
Material : Cast Iron Top, Mild Steel Body
Hospital Dressing Drums - Stainless Steel
Price 550 INR / Unit
Minimum Order Quantity : 1 Unit
Use : For Sterilization and Safe Storage of Dressings
Shape : Cylindrical
Temperature Range : Up to 134C (Autoclave Compatible)
Material : Stainless Steel
![]() |
SURGICAL WHOLESALE MART PRIVATE LIMITED
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |





Send Inquiry